Free and Latest article publishing for websites and ezines!

Study on Attitude Measurement System for Augmented Reality and Its Calibration Method

Augmented Reality (AR) is an important branch of the Virtual Reality (VR) and is attracting much attention of the researchers all over the world in recent years. Its application is expanding from indoor environments to outdoor systems. One of the key technologies in AR system is attitude measurement. However, traditional attitude measurement devices can not be applied in outdoor AR systems due to their limited working ranges and errors caused by environmental interferences. An attitude measurement system based on the measurements of the gravity field and the magnetic field of the earth with the characteristics of large working range, small size and low power consumption is presented. Algorithms for its calibration are studied. The proposed system can not only be applied in AR applications, but also in various applications such as unmanned vehicles, dead reckoning systems, and oil drilling.The error sources of the proposed attitude measurement system are first analyzed in detail. Then an error model based on physical principles is studied. Finally a calibration method based on ellipsoid fitting and invariant of the geomagnetic dip angle at a specific location is presented. During the calibration procedure, a set of measurements of three-axis accelerometers and magnetometers are recorded at various attitudes. Then the hard iron offsets, the stretch matrix and the hanger matrix of the soft iron are solved by fitting an ellipsoid to the measured data of the magnetometers, and the aligner matrix of the soft iron are determined using the fact that the dip angle is constant at the current location. The proposed calibration method can be performed even when no heading reference is provided.A method to remove outliers from the measurements of the magnetometer based on random sampling consensus (RANSAC) and orthogonal distance is presented, which greatly improves the accuracy and stability of the calibration method for magnetometers.A calibration method for three-axis accelerometers with absolute tilt reference is provided and the attitude selection method for accelerometer calibration is discussed. The calibration method for the offset of the accelerometers without reference is also proposed.An adaptive Kalman filter based on the magnitude of the measurements is presented to keep the heading stable when there is a sudden magnetic disturbance in the horizontal plane, and a hybrid attitude measurement system is designed.Two attitude measurement systems are implemented respectively, one is based on two-axis accelerometers and the other is based on three-axis accelerometers and three gyroscopes. Experimental results show the effectiveness of the proposed algorithms.

Recommended Articles from the Basic Sciences Category:

Most Viewed ScienceArticles in the Basic Sciences Category:

  1. Inflow Performance Relationship and Application for Low Permeability-Defomed Media Reservoir
  2. Numerical Simulation of Engine Con-rod Fracture Splitting Process and Analysis on Effect Factors
  3. An Evaluation of Ecotourism Characteristics in Nature Reserves and Tourism Impacts on Breeding Behavi
  4. Research on Seed Germination Ecology
  5. Oil and Gas Geological Condition and Prospect Evaluation in the Peripheral Down-Faulted Basins Group
  6. Investigation of Hyperspectral Remote Sensing Data Classification Using Multiple Classifiers Combinat
  7. Roles of RNA Secondary Structure in Dengue Virus C Gene and Capsid Protein in Viral Replication
  8. Lagrange Interpolation and Hermite Interpolation Along the Algebraic Manifold
  9. Research on the Electro-optic Effect of Silicon
  10. Study on the Function of miR-483 and miR-34a
  11. Krylov Subspace Methods for Large Matrix Eigenvalue and Linear System Problems
  12. Effect of Iron on Growth and Lipid Accumulation in Several Microalgae with Different Metabolic Type
  13. Study on the Degradative Characteristics and Pathway of PAHs Degrading Bacteria
  14. Role of RIG-I-like Receptors during Type I Interferon Response Induced by Dengue Virus Infection
  15. Key Parameters of Photobioreactor Cultivation of Macroalgal Cells


© 2004-2009 Latest-Science-Articles.com - All Rights Reserved Worldwide.